Humidity Controller ... |
|
|
|
|
SZ
2710
/
2910
(Humidity
Indicator) |
|
|
|
Main Features |
► |
Humidity Indicator with keypad calibration. |
|
Input & Output |
► |
Humidity Sensor Input : 1 RH Probe. |
|
Application |
► |
For humidity indication. |
|
General Specification |
► |
Humidity range 30% to 90% (SZ 2710) & 0% to 99% (SZ 2910). |
|
► |
Accuracy : +/- 5%(SZ 2710) & +/- 3%(SZ 2910) . |
|
► |
230VAC Standard. Other models with 12VDC, 24VDC, 110VAC on request. |
|
► |
Panel cutout : 29 X 71 mm Screw terminals : Admit 1X 2.5 mm2 wire. |
|
|
|
|
|
|
|
|
|
SZ
2711 / 2911
(Humidity
Indicator) |
|
|

Manual
/ Wiring Diagram |
Main Features |
► |
Switch
off
relay
at
setpoint. |
|
► |
Alarm
output
for
High
/
Low
Humidity. |
|
► |
Dehumidification
/
Humidification. |
|
Input & Output |
► |
Relay
output
:
8(3)A. |
|
► |
Alarm
relay
:
5A. |
|
► |
Humidity
Sensor
Input
: 1
RH
Probe. |
|
Application |
► |
For
humidification
&
dehumidification
systems. |
|
General Specification |
► |
Humidity
range
30%
to
90%
(SZ
2711)
& 0%
to
99%
(SZ
2911). |
|
► |
Accuracy
:
+/-
5%(SZ
2711)
&
+/-
3%(SZ
2911)
. |
|
► |
230VAC
Standard.
Other
models
with
12VDC,
24VDC,
110VAC
on
request. |
|
► |
Panel
cutout
: 29
X 71
mm
Screw
terminals
:
Admit
1X
2.5
mm2
wire. |
|
|
|
|
|
|
SZ 9912
(Temperature
/ RH
Controller) |
|

Manual
/ Wiring Diagram |
Main Features |
► |
Alarm
Indication
for high /
low
temperature
& Humidity. |
|
► |
Relay Out
put for
maintain
temperature
& Humidity. |
|
Input & Output |
► |
Relay output
: 8(3)A for
Temperature
and RH. |
|
► |
Temp. Sensor
Input : 1
PT-100. |
|
► |
RH Sensor (SZ
- HS-220). |
|
Application |
► |
For
humidification
&
dehumidification
systems. |
|
General Specification |
► |
Humidity
Range : 30%
to 90%
.Temperature
range 0°C to
+99.9°C. |
|
► |
Accuracy :
+/- 2%. |
|
|
230VAC
Standard.
Other models
with 12VDC,
24VDC,
110VAC on
request. |
|
► |
Panel cutout
: 29 X 71 mm
Screw
terminals :
Admit 1X 2.5
mm2 wire. |
|
|
|
|
|
|
|
SZ 9922
(Temperature
/ RH
Controller) |
|

Manual
/ Wiring Diagram |
Main Features |
► |
Alarm
Indication
for
high
/
low
temperature
&
Humidity. |
|
► |
Relay
Out
put
for
maintain
temperature
&
Humidity. |
|
Input & Output |
► |
Relay
output
:
8(3)A
for
Temperature |
|
► |
Relay
output
:
8(3)A
for
RH. |
|
► |
Temp.
Sensor
Input
: 1
PT-100. |
|
► |
RH
Sensor
(SZ
-
HS-100). |
|
Application |
► |
For
humidification
&
dehumidification
systems. |
|
General Specification |
► |
Humidity
Range
: 0%
to
100%.
Temperature
range
0°C
to
+99.9°C. |
|
► |
230VAC
Standard.
Other
models
with
12VDC,
24VDC,
110VAC
on
request. |
|
► |
Panel
cutout
: 29
X 71
mm
Screw
terminals
:
Admit
1X
2.5
mm2
wire. |
|
|
|
|
|
|
|
|